HYDROS® BW HS 500-2000

Demineralization unit fit to treat water from brackish well water and liquid effluents with a salinity up to 8000 ppm


The unit is composed of:

Pretreatment section
Composed of a set of polyethylene containers 20" with polyester cartridge with a fil- tration degree up to 60 micron and wound polypropylene filter cartridges with a filtration degree up to 5 micron.

Pressurization section
Composed of a vertical multistage centrifual pump in AISI 316.

Permeation section
Composed of a set of reverse osmosis spiral wound polyammide membranes housed in glass fibre vessels jointed by means of stain- less steel pipings to high pressure section and PVC pipings to low pressure section.

Hydraulic control board
Including:

  • Permeate, reject and recycle flowmeters.
  • Pressure, recycle and reject regulators.
  • Pressure gauges indicating the differential pressure on the filters.
  • Pressure gauges indicating the pump operating pressure.
  • Protection pressure switch for feed water low pressure.


Electric control board
Composed of:

  • Magnetothermic switch.
  • Thermal protection.
  • Tension light.
  • Manual ON/OFF with light.
  • Hour counter.
  • Automatic ON/0FF with light.
  • Conductivity meter indicating the permeate quality.
  • Timer.
  • Ancillary controls transformer.

 

Main operations of the units are controlled by a PLC Siemens.

Technical characteristics

 

HYDROS BW HS 500 HYDROS BW HS 750 HYDROS BW HS 1000 HYDROS BW HS 1300 HYDROS BW HS 1500 HYDROS BW HS 2000
Permeate
(litres/h)
500 750 1000 1300 1500 2000
Test conditions
- Temp(°C)
15 15 15 15 15 15

- Salinity
(ppm)
8000 8000 8000 8000 8000 8000
Power
(KW)
1,5 1,5 2,2 2,2 3 3
Voltage
(V/Hz)
400/50 400/50 400/50 400/50 400/50 400/50
Dimensions mm
- L
850 850 850 850 2200 2200

- P
900 900 900 900 900 900

- H
1500 1500 1500 1500 1500 1500
Weight (kG) 180 200 230 250 270 290